Solar Pumping Solutions

solar hot water

Esteem GB315 product photoHills Esteem Evacuated Tube Solar Hot Water - Natural / LPG Gas Boosted

315Lt Gas Boosted 30 Tubes

Product Description
Natural / LPG Gas Boosted, 30 tube collector, 315 litre stainless steel tank, 10 year warranty on major components.

Allocated REC's for this system: 37
Suitable for 4-5 persons

*Available rebates with this system
Federal Gov. - $1,000.00
NSW State Gov. - $1,000.00
Approx REC’s - $1,625.00

Full cost of system $6,569.30

*System cost after rebates $2,944.30 inc GST

All systems must be installed by a qualified plumber to maintain elegibility for rebates and insurance.

Why Hills Evacuated Tube Solar Hot Water Systems are the best!

  • Evacuated tubes will save you up to 90% on your annual water heating costs
  • Evacuated tubes are tested to -15 degrees C. you won't have any problems with freezing in winter. No anti-freeze chemicals like Glycol are used or needed.
  • They are also tesed hail resistant up to 25mm.
  • "...The ESTEEM TM Solar Collector is on Average 104% more efficient per m2 of aperture than the Flat Plate Solar Collector..."click here for full information on system efficiency.
  • If you break one or two tubes, unlike a flat plate system, ours will continue to operate and you can easily and economically replace any broken tubes.
  • If you don't have the ideal Northerly aspect on your roof, because of its cylindrical design the collector can be mounted in other positions and still function.
  • You won't have to re-inforce your roof as the tank sits on the ground
  • Because the system is modulart is simple to install without the need for cranes or heavy lifting.
  • Hills use marine grade, stainless steel tanks - they provide a natural oxide barrier to rust and eliminate the need for a sacrificial anode which saves the cost of replacement every 5 years.
  • You can use gas, electricity or waste heat from a wood stove to provide back up heating.
  • Eligible for generous government rebates up to $3800.
  • Some flat plate systems may offer more REC's however this has been calculated on 'area' covered by extremely large flat panels. As our systems are more efficient they cover less area.
  • Hills provide a 10 year warranty on all major components as well as the backing of a known and trusted Australian company.

Hills Esteem Evacuated Tube Solar Hot Water Systems

Climate change due to greenhouse emissions presents an immediate and growing threat to our fragile planet. The sun provides a limitless source of free non-polluting energy every day. A Hills Solar Evacuated Tube Hot Water System can efficiently capture this free energy and provide you with up to 80% savings on your hot water heating costs. Considering Australia is one of the sunniest countries on the planet it makes sense to utilise this resource by installing a Hills EsteemT Solar Evacuated Tube Hot Water System. Not only will you save money but you will also reduce your family's CO2 emissions by up to 3 tonnes per year.

Gas Boosting

Hills Solar offers a choice of gas boosting using Bosch continuous highflow gas booster, 21e or 26e on all GB315 Systems to ensure a continual flow of hot water on low thermal days. When water below 60° C is drawn from the tank, the gas booster will boost the water temperature to 60° C ensuring that only the water drawn is heated; therefore, saving energy.

Evacuated Solar Tubes

Evacuated tube technology delivers significantly better performance than traditional absorbers on the market today. Their advanced design incorporates tubes that consist of 2 layers of borosilicate glass with a vacuum layer between them. The vacuum acts like a thermos flask, retaining up to 97% of the thermal energy, resulting in an increased efficiency.

The Sun’s solar energy is then transferred to the manifold via the heat pipe located in each tube. The small amount of evaporative liquid in each tube is super heated by the Sun’s solar energy and forms into a vapour. The vapour rises to the top of each pipe. evacuated tube tech drawingHeat transfer then occurs between the pipe and water passing through the manifold. The water is then transferred to the tank.

The cylindrical design of the tubes ensures effective collection of the Sun’s solar energy throughout the entire day.

 

Technical Information

Bosch Gas Booster
Bosch product Bosch 21e Bosch 26e
Bosch part number YS217ORA YS267ORA
Installation External External
Ignition Electronic Electronic
L/min (25°C rise) 21 26
Number of bathrooms 2 2-3
Minimum operating inlet water pressure (kPa) 100 100
Mj/H 170 200
Star rating 5.56 5.53
Minimum flow (L/min) 2.5 2.5
Minimum constant water pressure for
maximum flow (kPa)
130 230
Antifrost Standard Standard
Gas type NG/LPG NG/LPG
Electrical
supply
230VAC-240V 50Hz 10amp
weatherproof power point
required within 500mm of the unit
Unit height (mm) 520 600
Unit width (mm) 350 350
Unit depth (mm) 170 170
Carton weight (kg) 19 22
Natural gas
pipe connection
20mm 3⁄4” 20mm 3⁄4”
LP gas pipe connection 20mm 3⁄4” 20mm 3⁄4”
Cold water pipe
connection
20mm 3⁄4” 20mm 3⁄4”
Hot water pipe
connection
20mm 3⁄4” 20mm 3⁄4”
Power
consumption
240VAC/36W in standby,
125W when anti freeze mode is on

 

315 Litre Tank
Size in Litres (Actual) 315 (327)
Height 1980mm
Diameter 580mm
Weight Empty 63kg
Weight Full 390kg
Hot Water Outlet 1495mm
Return Flow to Tank 465mm
Cold Water Inlet 365mm
Electric Cable Entry 255mm

 

Warranty * Parts Labour
Tank 10 years 1 year
EST Collectors 10 years 1 year
Gas Booster Heat Exchaner 10 years 3 years
Gas Booster - Other Parts* 3 years 3 years
Pump 1 year 1 year
Mounting Frame 10 years 1 year

*Conditions Apply. For full details please visit
www.hilllssolar.com.au or view the warranty card.

Suggested Tank Size
160 Litre# ~ Electric /GasBoosted ~ 1 to 2 People
250 Litre# ~ Electric / Gas Boosted ~ 3 to 4 People
315 Litre# ~ Electric / Gas Boosted ~ 5 to 6 People

#Suggested usage only.

System Information

Product Description 22 Tube Collector 30 Tube Collector 30 Tube Collector 40 Tube Collector
Product Code - LPG GB-315-21LP-22 GB-315-21LP-30 GB-315-25LP-30## GB-315-25LP-40##
Product Code - NG GB-315-21NG-22 GB-315-21NG-30 GB-315-25NG-30## GB-315-25NG-40##
Weight - Standard Frame, Manifold & Tubes 82kg 108kg 108kg 148kg
Height of Collector (including Manifold)
2000mm

2000mm 2000mm 2000mm
Width of Collector 1845mm 2485mm 2485mm 3470mm**
Distance between Inlet and Outlet Ports 1775mm 2415mm 2415mm 3400mm**
Surface area of Collector 3.69m2 4.97m2 4.97m2 6.74m2
Absorber area of Collector 1.76m2 2.40m2 2.40m2 3.2m2
Aperture area of Collector 2.086m2 2.844m2 2.844m2 3.792m2
Water that Manifold in Collector holds 1260ml 1770ml 1770ml 2330ml
Weight of Low Pitched Roof Frame 10.5kg 11.1kg 11.1kg 17.1kg
Weight of A-Frame 11.5kg 12.1kg 12.1kg 19.6kg
No. of REC’s for an installation per zone 22 Tube Collector 30 Tube Collector 30 Tube Collector 40 Tube Collector
Zone 1 - 315L 21e and 26e Gas Boosted
30 37 37 43
Zone 2 - 315L 21e and 26e Gas Boosted
32 39 39 44
Zone 3 - 315L 21e and 26e Gas Boosted
30 37 37 43
Zone 4 - 315L 21e and 26e Gas Boosted
26 32 32 38